100015.00, 1/2 HP, 1800 Rpm, 56 FR, DP, 115-208-230 Vac, 1 PH, Resilient Base, General Purpose
Engineering Data
Volts 115 Volts 208-230 Volts
F.L. Amps 8.8 F.L. Amps 4-4.4 F.L. Amps
S. F Amps 9.8 S. F Amps 4.6-4.9 S. F Amps
RPM 1800 Hertz 60
HP 1/2 Duty CONTINUOUS TYPE CD
KW 0.37
Frame S56 Serv. Factor 1.25 Phase 1
Max Amb 40 Design N Code K
Insul Class B Protection NOT Therm.Prot.
Eff 100% 62 Eff 75% PF 60
UL Y-(LEESON UL REC) CSA Yes Bearing OPE 6203
CC Number CE Bearing PE 6203
Load Type Inverter Type NONE Speed Range NONE
Motor Wt. 24 LB Enclosure DP Lubrication VERIFY
Nameplate A-92005-12 Mounting RESILIENT BASE Rotation SELECTIVE CCW
Assembly LO100015 Shaft Dia. 5/8 IN Ext. Diag. 005005.44
Cust Part No Outline 031623-600 Ext. Diag2
Packaging B Winding CE484206
Carton Label Leeson Gen Purpose GROUP: 3
Iris Paint BLUE - LEESON (ENAMEL) Test Card
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
Rework Status Rework TYPE
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM OZ-FT Inertia (WK˛) -1 LB-FT^2
Torque 24(Full Load) 66(Break Down) 62(Pull Up) 80(Locked Rotor)
CURRENT (amps) 4.4(Full Load) 0(Break Down) 0(Pull Up) 19.5(Locked Rotor)
Efficiency (%) 0(Full Load) 57.1(75% Load) 48.4(50% Load) 33.1(25% Load)
PowerFactor (Full Load) 51.4(75% Load) 42.4(50% Load) 32(25% Load)
Load Curve Data @60 Hz, 230 Volts, 1/2 Horsepower
Load Amps KW RPM Torque EFF PF Rise By Resis Frame Rise
0.0 4.0 0.197 1794 0.0 0.0 21.4 0.0 -
0.25 3.9 0.287 1784 6.0 33.1 32.0 0.0 -
0.5 4.0 0.39 1772 12.0 48.4 42.4 0.0 -
0.75 4.17 0.493 1760 18.0 57.1 51.4 0.0 -
1.0 4.41 0.606 1745 24.0 62.0 60.1 56.9 -
1.25 4.79 0.731 1730 30.0 63.1 66.4 0.0 -
1.5 5.25 0.866 1708 36.0 63.1 71.7 0.0 -